- Home
- Services
- DensGlass Sheathing
DensGlass Sheathing Replacement in Kennesaw
When water gets behind stucco or EIFS on a Kennesaw building, the sheathing takes the damage first. We open the wall, replace wet board with glass-mat gypsum sheathing and rebuild the weather barrier, flashing and finish.
- Wet sheathing removed
- Glass-mat board installed
- New barrier & flashing
- Finish matched to facade
Request a commercial quote
Kennesaw commercial stucco & EIFS. Property managers, boards, owners & builders.
The damage you can’t see from the parking lot
On many commercial and multifamily buildings around Kennesaw, the sheathing behind the cladding is OSB, plywood or paper-faced gypsum. Those boards hold up while they stay dry. Once water gets past a failed window perimeter, a parapet cap or a split sealant joint, they absorb it, soften and lose their hold on fasteners, and in time the framing behind them starts to deteriorate too.
None of that shows on the face of the wall until late. A slight bulge, a soft spot when pressed, rust staining below a fastener or a tenant’s recurring leak is often the first sign. Moisture probes confirm how far the damage spreads before anything is cut.
We remove the cladding over the damaged area, cut out wet sheathing back to sound material, treat or replace affected framing, and install glass-mat gypsum sheathing, which resists moisture far better than paper-faced board. Then we rebuild the weather barrier, flash the openings correctly and reinstall stucco or EIFS matched to the surrounding wall.

Sheathing & substrate repairs in Kennesaw
The facade only tells you there is a problem. These are the layers we rebuild once a wall is open.
Water-damaged sheathing
Swollen OSB, delaminated plywood and softened gypsum board cut back to sound material and replaced with glass-mat board.
Weather-resistive barrier
New barrier lapped over the sheathing and tied into the existing barrier at every edge of the repair.
Window & storefront openings
Sill pans and jamb flashing integrated with the barrier so water that reaches an opening drains out.
Parapets & roof-to-wall joints
Flashing corrected where a roof, balcony or breezeway meets the wall, a common source of wet sheathing.
Termite-damaged substrate
Sheathing and trim damaged by termites replaced, and cladding that runs below grade corrected.
Framing documented
Corroded steel studs or decayed wood framing are photographed and referred to the owner’s engineer before the wall is closed.
Why glass-mat board goes back in
Putting new OSB or paper-faced gypsum back behind the cladding puts the same vulnerable material in the same spot on a wall that has already shown it can get wet. Glass-mat gypsum sheathing has fiberglass facings in place of paper and a moisture-resistant core, so a wet spell does not break it down or feed mold the way wood and paper can.
It is not waterproof on its own. The weather barrier, flashing and sealant joints are still what keep water out, and every replacement we do includes them. Where the sheathing is part of a building’s structural design, or where we find damaged studs, tracks or framing, the owner’s engineer specifies that repair and we rebuild the wall to it. You see photos of the open wall before anything is closed.
| Board | When it stays wet | Our approach |
|---|---|---|
| OSBCommon on older wood frame | Swells and loses strength | Cut out and replaced |
| Plywood | Delaminates over time | Replaced or per engineer |
| Paper-faced gypsum | Facing and core break down | Replaced with glass-mat |
| Glass-mat gypsumDensGlass-type board | Resists rot and mold | Installed at the repair |
| Barrier & flashingOver any board | Sheds water to the weeps | Rebuilt every time |
How a sheathing replacement runs on site
The wall is open for as short a time as possible and protected at the end of every day, with the work phased around tenants and residents.
Survey & map
We take moisture readings across the elevation to find the edges of the wet area and the leak source before any cladding comes off.
- Readings mapped on photos
- Leak source identified
- Itemized written scope
Open & replace
Cladding is removed over the damaged area, wet sheathing is cut back to sound material, and glass-mat board is installed.
- Daily weather protection
- Framing issues documented
- Changes approved first
Barrier, flash & finish
New barrier and flashing are lapped into the existing wall, then the stucco or EIFS is rebuilt and color matched.
- Barrier lapped correctly
- Flashing at every opening
- Color & texture matched
Soft or bulging areas on your facade?
The longer sheathing stays wet, the more of the wall it takes with it. A moisture survey shows how far it has gone.
Where Kennesaw walls stay wet longest
Humid air, shaded elevations and recurring storms keep some walls from ever drying out.
On apartment and condominium buildings near Kennesaw State University and along Chastain Road and Jiles Road, we most often find wet sheathing under balconies, beside breezeways and below windows on shaded elevations. On retail and office buildings along Cobb Parkway and Barrett Parkway, it tends to be under parapets and behind storefront perimeters. Knowing the pattern helps us scope openings accurately.
Under balconies
Balcony ledgers and deck edges that send water into the wall below.
Below parapets
Cracked caps and coping joints that wet the top of the wall.
Rot & termites
Long-wet sheathing and framing that invite decay and termite damage.
- Kennesaw
- Chastain Road
- Jiles Road
- Kennesaw State University area
- Cobb Parkway
- Barrett Parkway
- Town Center
- Big Shanty Road
- Acworth
- Marietta
Sheathing replacement FAQ for Kennesaw
Questions Kennesaw owners and managers ask when wet sheathing is found.
Does replacing sheathing in Kennesaw require a permit?
How do you know how much sheathing to replace?
Why glass-mat gypsum instead of OSB or plywood?
Can residents or tenants stay in place during the repair?
Will the repaired area match the rest of the wall?
Request a sheathing repair quote in Kennesaw
Tell us where the wall is soft, stained or leaking. We will probe it and send a written, itemized repair scope.